RELAY WIRING
ALARM / CONTROL RELAYS
REMOTE TOTALIZER RELAY
FIG. 7
Relay contacts are shown in
de-energized condition
to alarm / control devices
Compuscale III
TB1
48 49
R1 C1
R2
C2
*POWER
SOURCE
CompuScale III
TB1
AC
* Some totalizers have an internal
power source.
Shaded area recommended for
inductive load (L)
R1 = R2 = 20 to 30 W
C1 = .01 to .1 mFd, 500 V
C2 = .001 to .01 mFd, 500 V
CompuScale III
TB1
48 49
+
*POWER
SOURCE
CompuScale III
TB1
DC
CompuScale III
TB1
PL-367 12 – 7