When the display initialization routine is complete, the display reverts to the last operating mode accessed. If
the CompuScale III is not programmed, the parameter entry display is accessed.
The CompuScale III display is divided into the following fields:
FIELD DESCRIPTION
MULTISPAN current span calibration selected. If Multispan 0 is selected, the field is blank.
RELAY current relay status (run mode). If relays are not used, or in non-alarm, the field is blank.
FEATURE parameter number (parameter entry), calibration type (calibrate mode), Load, Speed,
Rate or Total (run mode)
ECAL indicates ECAL (simulated rate signal) is on. If ECAL is off, the field is blank.
BELT REV. full belt revolutions remaining before calibration completion (calibrate mode).
CALIB calibrate mode indicator. When displayed, totalizers are on HOLD (unless otherwise specified).
VALUE the current value associated with the feature selected.
UNITS the units of measure associated with the value displayed
AUX 1 parameter name (parameter entry), auxiliary message (calibrate mode), not used (run mode).
AUX 2 parameter value range (parameter entry), additional information or error message (any mode).
BAR GRAPH represents current rate, displayed as percent of span (run mode).
150%100%RATE0%
-50%
FEATURE
ECAL
VALUE
AUX 1
AUX 2
RELAY
CALIB.
BELT REV.
UNITS
RATE BAR
GRAPH
MULTISPAN
PL-367 4 – 4