COMPUSCALE III / SPEED SENSOR INTERCONNECTION
MD - 2000A
MD - 36
1. Remove the Compuscale III TB1 - 32,33 jumper prior to connecting ther speed sensor.
2. Connect Compuscale III TB1 - 31 to the speed sensor junction:
Position 2 for clockwise speed sensor shaft rotation
Position 3 for counter clockwise speed sensor shaft rotation
3. If a speed sensor is not used the Compuscale III TB1 - 32,33 jumper must be in place.
CCW
CW
shaft
FIG. 5