PL-521 4
SPECIFICATIONS
Model :
XPS - 10 XPS - 15 XPS - 30 XPS - 40 XCT - 8 XCT - 12
Measurement
Range,
0.3 - 10 0.3 - 15 0.6 - 30 0.9 - 40 0.45 - 8 0.45 - 12
m (ft): (1-33) (1-50) (2-100) (3-130) (1.5-26) (1.5-40)
Frequency
(kHz):
43 43 30 22 43 43
Beam Angle: 12° 6° 6° 6° 12° 6°
Environmental:
-location: indoor / outdoor
-altitude: 2000 m maximum
-ambient
temperature:
-40 to 95 °C (-40 to 203 °F) -40 to 145 °C (-40 to 293 °F)
-ambient
pressure:
800 kPa (8 Bar, 120 PSI)
200 kPa (2 Bar, 30 PSI) for flange mount
-pollution degree: 4
Construction:
-exposure: Kynar®
-mounting: 1" NPT or BSP conduit
connection
1-1/2” NPT or BSP conduit
connection
1” NPT or BSP conduit
connection
-options: » factory bonded to suit ANSI, DIN and JIS standards
» polyethylene foam facing for dusty or steamy environments
» submergence shield, where flooding can occur (only available for XPS-10, XPS-15)
» split flange for field mounting to suit ANSI, DIN and JIS standards (not available for XPS-40)
Included:
2-wire twisted pair / braided and foil shielded, 0.5mm² (20 AWG),
PVC jacket
2-wire twisted pair / braided
and foil shielded, 0.5mm² (20
AWG), PVC jacket
-cable:
Maximum separation:
100 m (330 ft)
Silicone jacket
RG-62 A/U coax
Maximum separation:
365 m (1200 ft)
Supply Source: transducer shall only be supplied by Milltronics certified controllers
Weight*, kg (lb): 0.8 (1.7) 1.3 (2.8) 4.3 (9.5) 8 (18) 0.8 (1.7) 1.3 (2.8)
Separation: 365 m (1200 ft) from transducer
Approvals: CE **, CSA, FM, CENELEC/ATEX
see nameplate or consult Milltronics for current approvals
* approximate shipping weight of transducer with standard cable length
** EMC performance available upon request
Kynar® is registered trademark of ELF Atochem